APPLIANCE PERFORMANCE (1)

Fuel type : Pellet (Premium grade or better) (2)
Recommended heating area-ft² : () 500 - 2,000
Hopper capacity : 60 lb (27kg)
Maximum burn time : () 51 h
Maximum heat input rate : (3) 39,260 BTU/h (11.5 kW)
Overall heat output rate < : (4) 6,648 BTU/h (1.95 kW) to 28,540 BTU/h (8.36 kW)
Average overall efficiency : (5) 70.3 % (HHV) (6) 75.8 % (LHV) (7)
Optimum efficiency : (8) (9) 78.4%
Burn rate : 1.2 - 4.7 lb/h
Average particulate emissions rate : (10) 0.96 g/h
Average CO : (11) 7.6 g/h
Average electrical power consumption for ignition cycle : (12) 2.60A (312W)
Average electrical power consumption for continuous operation : (12) 1.3A - 2.5A (51W - 140W)

(1) Values are as measured per CSA B415.1-10, except for the recommended heating area, hopper capacity, maximum burn time and maximum heat input rate. Results may vary depending on pellet quality, density, length, and diameter.

(2) Grades of pellet fuel are determined by organizations such as Pellet Fuels Institute (PFI), ENplus and CANplus.

(3) Based on the maximum burn-rate and a dry energy value of pellet at 8,600 BTU/lb.

(4) As measured per CSA B415.1-10 stack loss method.

(5) Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand. LHV % is based on manufacturer’s estimation.

(6) Higher Heating Value of the fuel.

(7) Lower Heating Value of the fuel.

(8) Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.

(9) Optimum overall efficiency at a specific burn rate (LHV).

(10) This appliance is officially tested and certified by an independent agency.

(11) Carbon monoxyde.

(12) Unless stated otherwise, measures were taken directly at the main power source and include all electrical components present in the appliance.

GENERAL FEATURES

Combustion technology Top-feed
High-efficiency certified appliance Yes, EPA 2020 approved
Electronic igniter Yes
Flue outlet diameter 3"
Type of chimney ULC/ORD-C441, CAN/ULC S609, UL 641 (TYPE L)
Baffle type Stainless steel
Approved for an alcove installation Yes
Approved for a mobile home installation Yes, with fresh air intake
Shipping Weight 275 lb (125 kg)
Door type Single, glass with cast iron frame
Safe and removable handle N.A.
Glass type Ceramic glass
Glass surface – dimensions (Width X Height) 17 1/4" X 9 1/2"
Glass air-wash system Yes
Noise level at 6 feet 47 bBa (+/- 3 dBa) - 60 dBa (+/- 3 dBa)
Overall dimension (Height) 33"
Overall dimension (Width) 25 7/8"
Overall dimension (Depth) 30"
Adjustable threaded legs Yes
Easy-to-access ash drawer N.A.
Voltage and frequency 120 VAC - 60 Hz
AC Current 1.3A/120VAC - 2.5A/120VAC
Main control board fuses 8A - 250V
USA standard (emissions) EPA
Canadian Standard (emissions) CSA B415.1-10
USA standard (safety) UL 1482, ASTM E1509
Canadian standard (safety) ULC S627
Tested and listed as per applicable standards By an accredited laboratory (CAN/USA)
Warranty Limited lifetime
Minimum clearances to combustibles*
(Data expressed in inches. 1 inch = 25.4 mm)
  Canada United-States
Clearance – back wall 3" 3"
Clearance - corner 3" 3"
Clearance – side wall 6" 6"
Clearance – top (measured from the platform on which the appliance is installed)** 48" 48"

* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).